Sensata pressure sensors

 

Rellena el formulario para solicitar información en esta página.

 
Declaro haber leído la Política de Privacidad

* Estos campos son obligatorios.

 

SENSATA capacitive pressure sensors for gas applications

File: (2CP-2CP50 datasheet)
File: (87/88CP datasheet)
File: (81/82CP datasheet)

These device have inside a capacitive sensor separate from the fluid with a plastic membrane. They are supplied with body in brass, steel or AISI316 stainless steel. They are available with female electrical automotive Packard connection  with 0,5..4,5V= output signal or 4..20mA current signal. To see all technical caracteristics, you can download the data sheets.

Serie

Code

Relative pressure

Signal out

Mech. connection

Electr. connection

2CP-5

A000013413

-1..12,8bar

0,5..4,5V=

7/16" 20UNF

Packard

2CP-5

A000013410

 0..17,3bar

0,5..4,5V=

7/16" 20UNF

Packard

2CP-5

A000013414

 0..20,7bar

0,5..4,5V=

7/16" 20UNF

Packard

2CP-5

A000013411

 0..34,5bar

0,5..4,5V=

7/16" 20UNF

Packard

2CP-50

A000013412

 0..45,0bar

0,5..4,5V=

7/16" 20UNF

Packard

88CP

A000013409

 0..18bar

4..20mA

7/16" 20UNF

Packard

88CP

A000015741

 0..30bar

4..20mA

7/16" 20UNF

Packard

88CP

A000015753

 0..50bar

4..20mA

7/16" 20UNF

Packard

82CP

A000015705

 -1..19bar

4..20mA

Tubo 50x7mm Ø

Packard

82CP

A000015401

 -1..34bar

4..20mA

Tubo 50x7mm Ø

Packard

82CP

A000013415

 -1..45bar

4..20mA

Tubo 50x7mm Ø

Packard

 

SENSATA capacitive pressure sensors for water applications

These device have inside a capacitive sensor separate from the fluid with a plastic membrane. These sensors have a brass steel body or steel body. They are available with male connection ¼ gas and electrical connection M12 o RAST 2.5 with 0,5…4,5V= output signal or 4..20mA current signal. They are particularly suitable for applications on pumps with inverters where a good transducer is required at reasonable prices. Depending on the versions, WRAS and NSF certificates are available. To see all technical caracteristics, you can download the datasheets.

Serie

Code

Relative pressure

Signal out

Mech. connection

Electr. connection

35CP

A000013398

 0..16bar

 4.20mA

G¼ MA

M12

116CP

A000013418

 0..10bar

0,5..4,5V=

G¼ MA

RAST 2.5

116CP

A000013419

 0..16bar

0,5..4,5V=

G¼ MA

RAST 2.5

Typical applications:

  • Booster pump
  • Smart meter
  • Heat pump
  • Coffee espresso machine


Main features:

  • High accuracy: +/-1.5%V
  • Small & compact size
  • 100% automated calibration
  • REACH/RoHS/CE compliant
  • Drinking water safe options available (126CP and 127CP only)